Design of Reservoir of Larisa at Agiokampos “Livadotopos”, Final Geotechnical Design of Main Dam and Diversion Tunnel
Geotechnical Evaluation, Geotechnical Design of the earth-fill Dam Body of ≈375m length and max. height of ≈38m (stability, settlement and seepage analyses) and Geotechnical design of Cut Slopes of the Dam. Geotechnical Evaluation and Underground Excavation and Primary Support Design for the 330m long Diversion Tunnel (NATM) of Agiokampos Dam.
June - August 2015
Ministry of Agricultural Development and Foods
1. «Hydroexigiantiki Consulting Engineers» Lazaros Lazarides 2. Gr. & M Kafetzopoulos- D.Mpenakis 3. K. V. Triantafyllou 4. «Vakakis and Associates S.A.» 5. K. Sotiropoulou 6. «Geomechaniki S.A.»
Geomechaniki SA